TOPLEVEL PARAMETERS ------------------- Method Information For: D:\MSDCHEM\1\METHODS\2_SCREEN.M Method Sections To Run: (X) Save Copy of Method With Data ( ) MSTOP Pre-Run Cmd/Macro = ( ) Instrument Control Pre-Run Cmd/Macro = ( ) Data Analysis Pre-Run Cmd/Macro = (X) Data Acquisition (X) Data Analysis ( ) MSTOP Post-Run Cmd/Macro = ( ) Instrument Control Post-Run Cmd/Macro = ( ) Data Analysis Post-Run Cmd/Macro = Method Comments: This is the default method END OF TOPLEVEL PARAMETERS -------------------------- INSTRUMENT CONTROL PARAMETERS ----------------------------- ============================================================================= 6890 GC METHOD ============================================================================= OVEN Initial temp: 40 'C (On) Maximum temp: 350 'C Initial time: 0.00 min Equilibration time: 0.50 min Ramps: # Rate Final temp Final time 1 5.00 320 4.00 2 0.0(Off) Post temp: 0 'C Post time: 0.00 min Run time: 60.00 min FRONT INLET (HP PTV) BACK INLET (UNKNOWN) Mode: Splitless Initial temp: 40 'C (On) Initial time: 0.00 min Ramps: # Rate Final temp Final time 1600.00 320 2.00 2 10.00 200 0.00 3 0.0(Off) Cryo: On Cryo use temp: 200 'C Cryo Timeout: 30.00 min (On) Cryo Fault: Off Pressure: 83.0 kPa (On) Purge flow: 50.0 mL/min Purge time: 1.00 min Total flow: 54.5 mL/min Gas saver: On Saver flow: 20.0 mL/min Saver time: 2.00 min Gas type: Helium COLUMN 1 COLUMN 2 Capillary Column (not installed) Model Number: Resteck Rxi-5ms Serienummer 864841 Max temperature: 350 'C Nominal length: 30.0 m Nominal diameter: 250.00 um Nominal film thickness: 0.25 um Mode: constant flow Initial flow: 1.5 mL/min Nominal init pressure: 82.5 kPa Average velocity: 44 cm/sec Inlet: Front Inlet Outlet: MSD Outlet pressure: vacuum FRONT DETECTOR (NO DET) BACK DETECTOR (NO DET) SIGNAL 1 SIGNAL 2 Data rate: 20 Hz Data rate: 20 Hz Type: test plot Type: test plot Save Data: Off Save Data: Off Zero: 0.0 (Off) Zero: 0.0 (Off) Range: 0 Range: 0 Fast Peaks: Off Fast Peaks: Off Attenuation: 0 Attenuation: 0 COLUMN COMP 1 COLUMN COMP 2 (No Detectors Installed) (No Detectors Installed) THERMAL AUX 2 Use: MSD Transfer Line Heater Description: Initial temp: 320 'C (On) Initial time: 0.00 min # Rate Final temp Final time 1 0.0(Off) POST RUN Post Time: 0.00 min TIME TABLE Time Specifier Parameter & Setpoint 7673 Injector Front Injector: Sample Washes 2 Sample Pumps 3 Injection Volume 1.0 microliters Syringe Size 10.0 microliters PostInj Solvent A Washes 3 PostInj Solvent B Washes 0 Viscosity Delay 0 seconds Plunger Speed Fast PreInjection Dwell 0.00 minutes PostInjection Dwell 0.00 minutes Sampling Depth 0.0 mm Back Injector: No parameters specified Column 1 Inventory Number : Column 2 Inventory Number : MS ACQUISITION PARAMETERS General Information ------- ----------- Tune File : dftpp.u Acquistion Mode : Scan MS Information -- ----------- Solvent Delay : 2.60 min EM Absolute : False EM Offset : 0 Resulting EM Voltage : 2329.4 [Scan Parameters] Low Mass : 30.0 High Mass : 550.0 Threshold : 150 Sample # : 2 A/D Samples 4 [MSZones] MS Quad : 150 C maximum 200 C MS Source : 230 C maximum 250 C END OF MS ACQUISITION PARAMETERS END OF INSTRUMENT CONTROL PARAMETERS ------------------------------------